NAME

Lab::Moose::Instrument::ZI_MFLI - Zurich Instruments MFLI Lock-in Amplifier

VERSION

version 3.624

SYNOPSIS

use Lab::Moose;

my $mfli = instrument(
    type => 'ZI_MFLI',
    connection_type => 'Zhinst',
    connection_options => {
        host => '132.188.12.13',
        port => 8004,
    });

$mfli->set_frequency(value => 10000);

# Set time constants of first two demodulators to 0.5 sec:
$mfli->set_tc(demod => 0, value => 0.5);
$mfli->set_tc(demod => 1, value => 0.5);

# Read out demodulators:
my $xy_0 = $mfli->get_xy(demod => 0);
my $xy_1 = $mfli->get_xy(demod => 1);
say "x_0, y_0: ", $xy_0->{x}, ", ", $xy_0->{y};

METHODS

If the MFLI has the Impedance Analyzer option, calling some of the following setter options might be without effect. E.g. if the Bandwith Control option of the Impedance Analyzer module is set, manipulating the time constant with set_tc will not work.

get_frequency

my $freq = $mfli->get_frequency();

Get oscillator frequency.

set_frequency

$mfli->set_frequency(value => 10000);

Set oscillator frequency.

get_voltage_sens

my $sens = $mfli->get_voltage_sens();

Get sensitivity (range) of voltage input.

set_voltage_sens

$mfli->set_voltage_sens(value => 1);

Set sensitivity (range) of voltage input.

get_current_sens

my $sens = $mfli->get_current_sens();

Get sensitivity (range) of current input.

set_current_sens

$mfli->set_current_sens(value => 100e-6);

Set sensitivity (range) of current input.

get_amplitude

my $amplitude = $mfli->get_amplitude();

Get amplitude of voltage output.

set_amplitude

$mfli->set_amplitude(value => 300e-3);

Set amplitude of voltage output.

get_amplitude_range

my $amplitude_range = $mfli->get_amplitude_range();

Get range of voltage output.

set_amplitude_range

$mfli->set_amplitude_range(value => 1);

Set amplitude of voltage output.

get_phase

my $phase = $mfli->get_phase(demod => 0);

Get demodulator phase shift.

set_phase

$mfli->set_phase(demod => 0, value => 10);

Set demodulator phase.

get_tc

my $tc = $mfli->get_tc(demod => 0);

Get demodulator time constant.

set_tc

$mfli->set_tc(demod => 0, value => 0.5);

Set demodulator time constant.

get_order

my $order = $mfli->get_order(demod => 0);

Get demodulator filter order.

set_order

$mfli->set_order(demod => 0, order => 4);

Set demodulator filter order.

get_xy

my $xy_0 = $mfli->get_xy(demod => 0);
my $xy_1 = $mfli->get_xy(demod => 1);

printf("x: %g, y: %g\n", $xy_0->{x}, $xy_0->{y});

Get demodulator X and Y output measurement values.