package App::Netdisco::Worker::Plugin::LoadMIBs; use Dancer ':syntax'; use App::Netdisco::Worker::Plugin; use aliased 'App::Netdisco::Worker::Status'; use Dancer::Plugin::DBIC 'schema'; use Storable 'thaw'; use MIME::Base64 qw/encode_base64 decode_base64/; use File::Spec::Functions qw(splitdir catfile catdir); use File::Slurper qw(read_lines write_text); use App::Netdisco::Util::Device 'get_device'; use App::Netdisco::Util::Snapshot 'make_snmpwalk_browsable'; # use DDP; register_worker({ phase => 'main' }, sub { my ($job, $workerconf) = @_; my $vendor = $job->extra; debug sprintf 'loadmibs - loading netdisco-mibs object cache%s', ($vendor ? (sprintf ' for vendor "%s"', $vendor) : ''); my $home = (setting('mibhome') || catdir(($ENV{NETDISCO_HOME} || $ENV{HOME}), 'netdisco-mibs')); my $reports = catdir( $home, 'EXTRAS', 'reports' ); my @maps = map { (splitdir($_))[-1] } grep { ! m/^(?:EXTRAS)$/ } grep { ! m/\./ } grep { -f } glob (catfile( $reports, '*_oids' )); my @report = (); if ($vendor) { push @report, read_lines( catfile( $reports, "${vendor}_oids" ), 'latin-1' ); } else { push @report, read_lines( catfile( $reports, $_ ), 'latin-1' ) for (qw(rfc_oids net-snmp_oids cisco_oids), @maps); } my @browser = (); my %children = (); my %seenoid = (); foreach my $line (@report) { my ($oid, $qual_leaf, $type, $access, $index, $status, $enum, $descr) = split m/,/, $line, 8; next unless defined $oid and defined $qual_leaf; next if ++$seenoid{$oid} > 1; my ($mib, $leaf) = split m/::/, $qual_leaf; my @oid_parts = grep {length} (split m/\./, $oid); ++$children{ join '.', '', @oid_parts[0 .. (@oid_parts - 2)] } if scalar @oid_parts > 1; push @browser, { oid => $oid, oid_parts => [ @oid_parts ], mib => $mib, leaf => $leaf, type => $type, access => $access, index => [($index ? (split m/:/, $index) : ())], status => $status, enum => [($enum ? (split m/:/, $enum ) : ())], descr => $descr, }; } foreach my $row (@browser) { $row->{num_children} = $children{ $row->{oid} } || 0; } debug sprintf "loadmibs - loaded %d objects from netdisco-mibs", scalar @browser; schema('netdisco')->txn_do(sub { my $gone = schema('netdisco')->resultset('SNMPObject')->delete; debug sprintf 'loadmibs - removed %d oids', $gone; schema('netdisco')->resultset('SNMPObject')->populate(\@browser); debug sprintf 'loadmibs - added %d new oids', scalar @browser; }); my @filters = <DATA>; $_ = [split m/\t/, $_] for @filters; $_ = {leaf => $_->[0], subname => $_->[1]} for @filters; chomp( $_->{subname} ) for @filters; schema('netdisco')->txn_do(sub { my $gone = schema('netdisco')->resultset('SNMPFilter')->delete; debug sprintf 'loadmibs - removed %d filters', $gone; schema('netdisco')->resultset('SNMPFilter')->populate(\@filters); debug sprintf 'loadmibs - added %d new filters', scalar @filters; }); #Â promote snapshots prior to loadmibs to be browsable schema('netdisco')->txn_do(sub { my @devices = schema('netdisco') ->resultset('DeviceBrowser') ->search({ -bool => \q{ array_length(oid_parts, 1) IS NULL } }) ->distinct('ip')->get_column('ip')->all; foreach my $ip (@devices) { my $dev = get_device($ip); next unless $dev->in_storage; debug sprintf 'loadmibs - promoting snapshot for %s to be browsable', $dev->ip; make_snmpwalk_browsable($dev); } }); #Â legacy snapshot upgrade schema('netdisco')->txn_do(sub { my $legacy_rs = schema('netdisco') ->resultset('DeviceBrowser') ->search({ -bool => \q{ jsonb_typeof(value) != 'array' } }); if ($legacy_rs->count) { my @rows = $legacy_rs->hri->all; my $gone = $legacy_rs->delete; #Â the legacy looks like encode_base64( nfreeze( [$data] ) ) foreach my $row (@rows) { my $value = (@{ thaw( decode_base64( from_json($row->{value}) ) ) })[0]; $value = (ref {} eq ref $value) ? { map {($_ => (defined $value->{$_} ? encode_base64($value->{$_}, '') : undef))} keys %$value } : (defined $value ? encode_base64($value, '') : undef); $row->{value} = to_json([$value]); } schema('netdisco')->resultset('DeviceBrowser')->populate(\@rows); debug sprintf 'loadmibs - updated %d legacy snapshot rows', scalar @rows; } }); return Status->done('Loaded MIBs'); }); true; __DATA__ ad_lag_ports SNMP::Info::munge_port_list adminAgentPhysAddress SNMP::Info::munge_mac adminAgentPhysAddress.0 SNMP::Info::munge_mac ag_mod2_type SNMP::Info::munge_e_type ag_mod_type SNMP::Info::munge_e_type agentInterfaceMacAddress SNMP::Info::munge_mac aipAMAPRemHostname SNMP::Info::munge_null airespace_ap_ethermac SNMP::Info::munge_mac airespace_ap_mac SNMP::Info::munge_mac airespace_bl_mac SNMP::Info::munge_mac airespace_if_mac SNMP::Info::munge_mac airespace_sta_mac SNMP::Info::munge_mac alHardwareFan1RpmAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwareFan2RpmAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwareFan3RpmAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwarePs1Voltage3vAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwarePs1Voltage5vAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwarePs2Voltage3vAlarm SNMP::Info::Layer3::Altiga::munge_alarm alHardwarePs2Voltage5vAlarm SNMP::Info::Layer3::Altiga::munge_alarm amap_rem_sysname SNMP::Info::munge_null ap_if_mac SNMP::Info::munge_mac aruba_ap_bssid_ssid SNMP::Info::munge_null aruba_ap_fqln SNMP::Info::Layer3::Aruba::munge_aruba_fqln aruba_ap_type SNMP::Info::munge_e_type aruba_card_type SNMP::Info::munge_e_type aruba_user_bssid SNMP::Info::munge_mac atPhysAddress SNMP::Info::munge_mac at_paddr SNMP::Info::munge_mac awcIfPhysAddress SNMP::Info::munge_mac awc_mac SNMP::Info::munge_mac b_mac SNMP::Info::munge_mac bs_mac SNMP::Info::munge_mac bsnAPDot3MacAddress SNMP::Info::munge_mac bsnAPEthernetMacAddress SNMP::Info::munge_mac bsnBlackListClientMacAddress SNMP::Info::munge_mac bsnMobileStationAPMacAddr SNMP::Info::munge_mac bsnMobileStationMacAddress SNMP::Info::munge_mac bsnMobileStationPacketsReceived SNMP::Info::Airespace::munge_64bits bsnMobileStationPacketsSent SNMP::Info::Airespace::munge_64bits cDot11ClientCurrentTxRateSet SNMP::Info::Layer2::Aironet::munge_cd11_txrate cDot11ClientDataRateSet SNMP::Info::Layer2::Aironet::munge_cd11_txrate cInetNetToMediaPhysAddress SNMP::Info::IPv6::munge_physaddr cLApIfMacAddress SNMP::Info::munge_mac c_id SNMP::Info::Layer2::HP::munge_hp_c_id c_inet_phys_addr SNMP::Info::IPv6::munge_physaddr cbgpPeer2LastError SNMP::Info::munge_octet2hex cbgpPeer2LocalAddr SNMP::Info::munge_inetaddress cd11_proto SNMP::Info::Layer2::Airespace::munge_cd11_proto cd11_rateset SNMP::Info::Layer2::Aironet::munge_cd11_txrate cd11_rxpkt SNMP::Info::Airespace::munge_64bits cd11_ssid SNMP::Info::munge_null cd11_txpkt SNMP::Info::Airespace::munge_64bits cd11_txrate SNMP::Info::Layer2::Aironet::munge_cd11_txrate cd11n_ch_bw SNMP::Info::Layer2::Airespace::munge_cd11n_ch_bw cdot11MbssidIfMacAddress SNMP::Info::munge_mac cdpCacheCapabilities SNMP::Info::munge_bits cdpCachePlatform SNMP::Info::munge_null cdpCachePowerConsumption SNMP::Info::CDP::munge_power cdpCacheVTPMgmtDomain SNMP::Info::munge_null cdpCacheVersion SNMP::Info::munge_null cdp_capabilities SNMP::Info::munge_bits cdp_domain SNMP::Info::munge_null cdp_ip SNMP::Info::munge_ip cdp_platform SNMP::Info::munge_null cdp_power SNMP::Info::CDP::munge_power cdp_ver SNMP::Info::munge_null cisco_bgp_peer2_lasterror SNMP::Info::munge_octet2hex cisco_bgp_peer2_localaddr SNMP::Info::munge_inetaddress clagAggPortListInterfaceIndexList SNMP::Info::CiscoAgg::munge_port_ifindex clagAggPortListPorts SNMP::Info::munge_port_list cldHtDot11nChannelBandwidth SNMP::Info::Layer2::Airespace::munge_cd11n_ch_bw cldcClientDataRateSet SNMP::Info::Layer2::Airespace::munge_cd11_rateset cldcClientProtocol SNMP::Info::Layer2::Airespace::munge_cd11_proto cpsIfSecureLastMacAddress SNMP::Info::munge_mac cps_i_mac SNMP::Info::munge_mac dot11MACAddress SNMP::Info::munge_mac dot11StationID SNMP::Info::munge_mac dot11StationID.2 SNMP::Info::munge_mac dot11_mac SNMP::Info::munge_mac dot11_sta_id SNMP::Info::munge_mac dot1dBaseBridgeAddress SNMP::Info::munge_mac dot1dBaseBridgeAddress.0 SNMP::Info::munge_mac dot1dStaticAddress SNMP::Info::munge_mac dot1dStpDesignatedRoot SNMP::Info::munge_prio_mac dot1dStpPortDesignatedBridge SNMP::Info::munge_prio_mac dot1dStpPortDesignatedPort SNMP::Info::munge_prio_port dot1dStpPortDesignatedRoot SNMP::Info::munge_prio_mac dot1dTpFdbAddress SNMP::Info::munge_mac dot1dTpFdbPort SNMP::Info::munge_mac dot1qVlanCurrentEgressPorts SNMP::Info::munge_port_list dot1qVlanCurrentUntaggedPorts SNMP::Info::munge_port_list dot1qVlanForbiddenEgressPorts SNMP::Info::munge_port_list dot1qVlanStaticEgressPorts SNMP::Info::munge_port_list dot1qVlanStaticUntaggedPorts SNMP::Info::munge_port_list dot1xAuthLastEapolFrameSource SNMP::Info::munge_mac dot1xPaePortCapabilities SNMP::Info::CiscoPortSecurity::munge_pae_capabilities dot3StatsDuplexStatus SNMP::Info::EtherLike::munge_el_duplex dot3adAggPortListPorts SNMP::Info::munge_port_list e_class SNMP::Info::Layer3::Timetra::munge_tmnx_e_class e_containers_type SNMP::Info::munge_e_type e_contents_type SNMP::Info::munge_e_type e_swver SNMP::Info::Layer3::Timetra::munge_tmnx_e_swver e_type SNMP::Info::munge_e_type edp_rem_sysname SNMP::Info::munge_null el_duplex SNMP::Info::EtherLike::munge_el_duplex entPhysicalVendorType SNMP::Info::munge_e_type ex_fw_mac SNMP::Info::munge_mac ex_stp_i_mac SNMP::Info::munge_prio_mac ex_vlan_tagged SNMP::Info::munge_port_list ex_vlan_untagged SNMP::Info::munge_port_list extremeEdpNeighborName SNMP::Info::munge_null extremeFanOperational SNMP::Info::Layer3::Extreme::munge_true_ok extremeFdbMacFdbMacAddress SNMP::Info::munge_mac extremePowerSupplyStatus SNMP::Info::Layer3::Extreme::munge_power_stat extremePowerSupplyStatus.1 SNMP::Info::Layer3::Extreme::munge_power_stat extremePowerSupplyStatus.2 SNMP::Info::Layer3::Extreme::munge_power_stat extremePrimaryPowerOperational SNMP::Info::Layer3::Extreme::munge_true_ok extremePrimaryPowerOperational.0 SNMP::Info::Layer3::Extreme::munge_true_ok extremeRedundantPowerStatus SNMP::Info::Layer3::Extreme::munge_power_stat extremeRedundantPowerStatus.0 SNMP::Info::Layer3::Extreme::munge_power_stat extremeStpDomainBridgeId SNMP::Info::munge_prio_mac extremeStpDomainDesignatedRoot SNMP::Info::munge_prio_mac extremeStpPortDesignatedBridge SNMP::Info::munge_prio_mac extremeStpPortDesignatedPort SNMP::Info::munge_prio_port extremeStpPortDesignatedRoot SNMP::Info::munge_prio_mac extremeVlanOpaqueTaggedPorts SNMP::Info::munge_port_list extremeVlanOpaqueUntaggedPorts SNMP::Info::munge_port_list fan1_alarm SNMP::Info::Layer3::Altiga::munge_alarm fan2_alarm SNMP::Info::Layer3::Altiga::munge_alarm fan3_alarm SNMP::Info::Layer3::Altiga::munge_alarm fan_state SNMP::Info::Layer3::Extreme::munge_true_ok fdp_capabilities SNMP::Info::munge_bits fdp_ip SNMP::Info::munge_ip fw_mac SNMP::Info::munge_mac fw_mac2 SNMP::Info::munge_mac fw_port SNMP::Info::munge_mac hpSwitchBaseMACAddress SNMP::Info::munge_mac hpSwitchBaseMACAddress.0 SNMP::Info::munge_mac hwPoePortEnable SNMP::Info::Layer3::Huawei::munge_hw_peth_admin hwPoePortPdClass SNMP::Info::Layer3::Huawei::munge_hw_peth_class hwPoePortPowerStatus SNMP::Info::Layer3::Huawei::munge_hw_peth_status hwPoeSlotConsumingPower SNMP::Info::Layer3::Huawei::munge_hw_peth_power hwPoeSlotMaximumPower SNMP::Info::Layer3::Huawei::munge_hw_peth_power hw_peth_port_admin SNMP::Info::Layer3::Huawei::munge_hw_peth_admin hw_peth_port_class SNMP::Info::Layer3::Huawei::munge_hw_peth_class hw_peth_port_status SNMP::Info::Layer3::Huawei::munge_hw_peth_status i6_n2p_phys_addr SNMP::Info::munge_mac i_duplex SNMP::Info::Layer2::Nexans::munge_i_duplex i_duplex_admin SNMP::Info::Layer2::Nexans::munge_i_duplex_admin i_mac SNMP::Info::munge_mac i_mac2 SNMP::Info::munge_mac i_octet_in64 SNMP::Info::munge_counter64 i_octet_out64 SNMP::Info::munge_counter64 i_pkts_bcast_in64 SNMP::Info::munge_counter64 i_pkts_bcast_out64 SNMP::Info::munge_counter64 i_pkts_multi_out64 SNMP::Info::munge_counter64 i_pkts_mutli_in64 SNMP::Info::munge_counter64 i_pkts_ucast_in64 SNMP::Info::munge_counter64 i_pkts_ucast_out64 SNMP::Info::munge_counter64 i_speed SNMP::Info::munge_speed i_speed_high SNMP::Info::munge_highspeed i_up SNMP::Info::munge_i_up ieee8021QBridgeVlanCurrentEgressPorts SNMP::Info::munge_port_list ieee8021QBridgeVlanCurrentUntaggedPorts SNMP::Info::munge_port_list ieee8021QBridgeVlanForbiddenEgressPorts SNMP::Info::munge_port_list ieee8021QBridgeVlanStaticEgressPorts SNMP::Info::munge_port_list ieee8021QBridgeVlanStaticUntaggedPorts SNMP::Info::munge_port_list ifHCInBroadcastPkts SNMP::Info::munge_counter64 ifHCInOctets SNMP::Info::munge_counter64 ifHCInUcastPkts SNMP::Info::munge_counter64 ifHCOutBroadcastPkts SNMP::Info::munge_counter64 ifHCOutMulticastPkts SNMP::Info::munge_counter64 ifHCOutOctets SNMP::Info::munge_counter64 ifHCOutUcastPkts SNMP::Info::munge_counter64 ifHighSpeed SNMP::Info::munge_highspeed ifMauAutoNegCapAdvertised SNMP::Info::MAU::munge_int2bin ifMauAutoNegCapReceived SNMP::Info::MAU::munge_int2bin ifMauTypeList SNMP::Info::MAU::munge_int2bin ifOperStatus SNMP::Info::munge_i_up ifPhysAddress SNMP::Info::munge_mac ifPhysAddress.1 SNMP::Info::munge_mac ifPhysAddress.2 SNMP::Info::munge_mac ifSpeed SNMP::Info::munge_speed ip SNMP::Info::munge_ip ipNetToMediaPhysAddress SNMP::Info::munge_mac ipNetToPhysicalPhysAddress SNMP::Info::munge_mac ip_n2p_phys_addr SNMP::Info::munge_mac ipv6NetToMediaPhysAddress SNMP::Info::munge_mac iqb_cv_egress SNMP::Info::munge_port_list iqb_cv_untagged SNMP::Info::munge_port_list iqb_v_egress SNMP::Info::munge_port_list iqb_v_fbdn_egress SNMP::Info::munge_port_list iqb_v_untagged SNMP::Info::munge_port_list jnxContainersType SNMP::Info::munge_e_type jnxContentsType SNMP::Info::munge_e_type lag_members SNMP::Info::CiscoAgg::munge_port_ifindex lag_ports SNMP::Info::munge_port_list layers SNMP::Info::munge_dec2bin lldpInfoRemoteDevicesSystemCapEnabled SNMP::Info::munge_bits lldpInfoRemoteDevicesSystemDescription SNMP::Info::munge_null lldpInfoRemoteDevicesSystemName SNMP::Info::munge_null lldpLocPortDesc SNMP::Info::munge_null lldpLocPortId SNMP::Info::munge_null lldpLocSysCapEnabled SNMP::Info::munge_bits lldpLocSysDesc SNMP::Info::munge_null lldpLocSysName SNMP::Info::munge_null lldpRemSysCapEnabled SNMP::Info::munge_bits lldpRemSysCapSupported SNMP::Info::munge_bits lldpRemSysDesc SNMP::Info::munge_null lldpRemSysName SNMP::Info::munge_null lldpXMedRemAssetID SNMP::Info::munge_null lldpXMedRemCapCurrent SNMP::Info::munge_bits lldpXMedRemCapSupported SNMP::Info::munge_bits lldpXMedRemFirmwareRev SNMP::Info::munge_null lldpXMedRemHardwareRev SNMP::Info::munge_null lldpXMedRemMfgName SNMP::Info::munge_null lldpXMedRemModelName SNMP::Info::munge_null lldpXMedRemSerialNum SNMP::Info::munge_null lldpXMedRemSoftwareRev SNMP::Info::munge_null lldp_lport_desc SNMP::Info::munge_null lldp_lport_id SNMP::Info::munge_null lldp_rem_asset SNMP::Info::munge_null lldp_rem_cap_spt SNMP::Info::munge_bits lldp_rem_fw_rev SNMP::Info::munge_null lldp_rem_hw_rev SNMP::Info::munge_null lldp_rem_media_cap SNMP::Info::munge_bits lldp_rem_media_cap_spt SNMP::Info::munge_bits lldp_rem_model SNMP::Info::munge_null lldp_rem_port_desc SNMP::Info::munge_null lldp_rem_serial SNMP::Info::munge_null lldp_rem_sw_rev SNMP::Info::munge_null lldp_rem_sys_cap SNMP::Info::munge_bits lldp_rem_sysdesc SNMP::Info::munge_null lldp_rem_sysname SNMP::Info::munge_null lldp_rem_vendor SNMP::Info::munge_null lldp_sys_cap SNMP::Info::munge_bits lldp_sysdesc SNMP::Info::munge_null lldp_sysname SNMP::Info::munge_null m_ports_status SNMP::Info::CiscoStack::munge_port_status mac SNMP::Info::munge_mac mac_table SNMP::Info::munge_mac mau_autorec SNMP::Info::MAU::munge_int2bin mau_autosent SNMP::Info::MAU::munge_int2bin mau_type SNMP::Info::MAU::munge_int2bin mbss_mac_addr SNMP::Info::munge_mac modulePortStatus SNMP::Info::CiscoStack::munge_port_status n2p_paddr SNMP::Info::munge_mac nUserApBSSID SNMP::Info::munge_mac nsIfMAC SNMP::Info::munge_mac nsIpArpMac SNMP::Info::munge_mac ns_at_paddr SNMP::Info::munge_mac ns_ch_type SNMP::Info::munge_e_type ns_com_type SNMP::Info::munge_e_type ns_grp_type SNMP::Info::NortelStack::munge_ns_grp_type ns_i_mac SNMP::Info::munge_mac ns_store_type SNMP::Info::munge_e_type ntwsApStatRadioServBssid SNMP::Info::munge_mac ntwsApStatRadioStatusBaseMac SNMP::Info::munge_mac nwss2300_apif_bssid SNMP::Info::munge_mac nwss2300_apif_mac SNMP::Info::munge_mac old_at_paddr SNMP::Info::munge_mac p_duplex_admin SNMP::Info::munge_bits pae_i_capabilities SNMP::Info::CiscoPortSecurity::munge_pae_capabilities pae_i_last_eapol_frame_source SNMP::Info::munge_mac peth_power_consumption SNMP::Info::Layer3::Huawei::munge_hw_peth_power peth_power_watts SNMP::Info::Layer3::Huawei::munge_hw_peth_power portCpbDuplex SNMP::Info::munge_bits portLinkState SNMP::Info::Layer2::Nexans::munge_i_duplex portSpeedDuplexSetup SNMP::Info::Layer2::Nexans::munge_i_duplex_admin ps1_3v_alarm SNMP::Info::Layer3::Altiga::munge_alarm ps1_5v_alarm SNMP::Info::Layer3::Altiga::munge_alarm ps1_status_new SNMP::Info::Layer3::Extreme::munge_power_stat ps1_status_old SNMP::Info::Layer3::Extreme::munge_true_ok ps2_3v_alarm SNMP::Info::Layer3::Altiga::munge_alarm ps2_5v_alarm SNMP::Info::Layer3::Altiga::munge_alarm ps2_status_new SNMP::Info::Layer3::Extreme::munge_power_stat ps2_status_old SNMP::Info::Layer3::Extreme::munge_power_stat qb_cv_egress SNMP::Info::munge_port_list qb_cv_untagged SNMP::Info::munge_port_list qb_v_egress SNMP::Info::munge_port_list qb_v_fbdn_egress SNMP::Info::munge_port_list qb_v_untagged SNMP::Info::munge_port_list rc2kChassisBaseMacAddr SNMP::Info::munge_mac rc2kCpuEthernetPortMgmtMacAddr SNMP::Info::munge_mac rcMltPortMembers SNMP::Info::munge_port_list rcStgBridgeAddress SNMP::Info::munge_mac rcStgDesignatedRoot SNMP::Info::munge_prio_mac rcStgPortDesignatedBridge SNMP::Info::munge_prio_mac rcStgPortDesignatedPort SNMP::Info::munge_prio_port rcStgPortDesignatedRoot SNMP::Info::munge_prio_mac rcVlanMacAddress SNMP::Info::munge_mac rcVlanNotAllowToJoin SNMP::Info::munge_port_list rcVlanPortMembers SNMP::Info::munge_port_list rc_base_mac SNMP::Info::munge_mac rc_cpu_mac SNMP::Info::munge_mac rc_mlt_ports SNMP::Info::munge_port_list rc_stp_i_mac SNMP::Info::munge_mac rc_stp_i_root SNMP::Info::munge_prio_mac rc_stp_p_bridge SNMP::Info::munge_prio_mac rc_stp_p_port SNMP::Info::munge_prio_port rc_stp_p_root SNMP::Info::munge_prio_mac rc_vlan_mac SNMP::Info::munge_mac rc_vlan_members SNMP::Info::munge_port_list rc_vlan_no_join SNMP::Info::munge_port_list rndBasePhysicalAddress SNMP::Info::munge_mac rptrAddrTrackNewLastSrcAddress SNMP::Info::munge_mac rptr_last_src SNMP::Info::munge_mac s3000_topo_mac SNMP::Info::munge_mac s3EnetShowNodesMacAddress SNMP::Info::munge_mac s3EnetTopNmmMacAddr SNMP::Info::munge_mac s5ChasComType SNMP::Info::munge_e_type s5ChasGrpType SNMP::Info::NortelStack::munge_ns_grp_type s5ChasStoreType SNMP::Info::munge_e_type s5ChasType SNMP::Info::munge_e_type s5CmSNodeMacAddr SNMP::Info::munge_mac s5EnMsTopNmmEnhancedMacAddr SNMP::Info::munge_mac s5EnMsTopNmmMacAddr SNMP::Info::munge_mac snAgentConfigModule2Type SNMP::Info::munge_e_type snAgentConfigModuleType SNMP::Info::munge_e_type snFdpCacheAddress SNMP::Info::munge_ip snFdpCacheCapabilities SNMP::Info::munge_bits snPortStpPortDesignatedBridge SNMP::Info::munge_prio_mac snPortStpPortDesignatedPort SNMP::Info::munge_prio_port snPortStpPortDesignatedRoot SNMP::Info::munge_prio_mac snVLanByPortBaseBridgeAddress SNMP::Info::munge_mac snVLanByPortStpDesignatedRoot SNMP::Info::munge_prio_mac sonmp_topo_e_mac SNMP::Info::munge_mac sonmp_topo_mac SNMP::Info::munge_mac std_at_paddr SNMP::Info::munge_mac stp_i_mac SNMP::Info::munge_mac stp_i_root SNMP::Info::munge_prio_mac stp_p_bridge SNMP::Info::munge_prio_mac stp_p_port SNMP::Info::munge_prio_port stp_p_root SNMP::Info::munge_prio_mac stp_root SNMP::Info::munge_prio_mac stpxSMSTConfigDigest SNMP::Info::CiscoStpExtensions::oct2str stpx_mst_config_digest SNMP::Info::CiscoStpExtensions::oct2str sysExtCardType SNMP::Info::munge_e_type sysServices SNMP::Info::munge_dec2bin tmnxChassisFanOperStatus SNMP::Info::Layer3::Timetra::munge_tmnx_state tmnxChassisPowerSupply1Status SNMP::Info::Layer3::Timetra::munge_tmnx_state tmnxChassisPowerSupply2Status SNMP::Info::Layer3::Timetra::munge_tmnx_state tmnxHwClass SNMP::Info::Layer3::Timetra::munge_tmnx_e_class tmnxHwSoftwareCodeVersion SNMP::Info::Layer3::Timetra::munge_tmnx_e_swver tmnxLldpRemSysCapEnabled SNMP::Info::munge_bits tmnxLldpRemSysCapSupported SNMP::Info::munge_bits tmnxLldpRemSysDesc SNMP::Info::munge_null tmnxLldpRemSysName SNMP::Info::munge_null tmnx_fan_state SNMP::Info::Layer3::Timetra::munge_tmnx_state tmnx_ps1_state SNMP::Info::Layer3::Timetra::munge_tmnx_state tmnx_ps2_state SNMP::Info::Layer3::Timetra::munge_tmnx_state trapeze_apif_bssid SNMP::Info::munge_mac trapeze_apif_mac SNMP::Info::munge_mac trpzApStatRadioServBssid SNMP::Info::munge_mac trpzApStatRadioStatusBaseMac SNMP::Info::munge_mac wfHwBabyBdSerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwBootPromRev SNMP::Info::Layer3::BayRS::munge_hw_rev wfHwDaughterBdSerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwDiagPromRev SNMP::Info::Layer3::BayRS::munge_hw_rev wfHwModDaughterBd1SerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwModDaughterBd2SerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwModSerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwModuleModSerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wfHwMotherBdSerialNumber SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_bb_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_boot SNMP::Info::Layer3::BayRS::munge_hw_rev wf_hw_db_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_diag SNMP::Info::Layer3::BayRS::munge_hw_rev wf_hw_md1_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_md2_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_mm_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_mobo_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wf_hw_mod_ser SNMP::Info::Layer3::BayRS::munge_wf_serial wlanAPESSID SNMP::Info::munge_null wlanAPFQLN SNMP::Info::Layer3::Aruba::munge_aruba_fqln wlanAPModel SNMP::Info::munge_e_type wlanStaAccessPointESSID SNMP::Info::munge_null wlsxSysExtSwitchBaseMacaddress SNMP::Info::munge_mac