NAME
Lab::Instrument::YokogawaGS200 - Yokogawa GS200 DC source
SYNOPSIS
use Lab::Instrument::YokogawaGS200;
my $gate14=new Lab::Instrument::YokogawaGS200(
connection_type => 'LinuxGPIB',
gpib_address => 22,
function => 'VOLT',
level => 0.4,
);
$gate14->set_voltage(0.745);
print $gate14->get_voltage();
DESCRIPTION
The Lab::Instrument::YokogawaGS200 class implements an interface to the discontinued voltage and current source GS200 by Yokogawa. This class derives from Lab::Instrument::Source and provides all functionality described there.
CONSTRUCTORS
new( %configuration_HASH )
HASH is a list of tuples given in the format
key => value,
please supply at least the configuration for the connection: connection_type => "LinxGPIB" gpib_address =>
you might also want to have gate protect from the start (the default values are given):
gate_protect => 1,
gp_equal_level => 1e-5,
gp_max_units_per_second => 0.05,
gp_max_units_per_step => 0.005,
gp_max_step_per_second => 10,
gp_max_units_per_second => 0.05,
gp_max_units_per_step => 0.005,
max_sweep_time=>3600,
min_sweep_time=>0.1,
Additinally there is support to set parameters for the device "on init":
function => undef, # 'VOLT' - voltage, 'CURR' - current
range => undef,
level => undef,
output => undef,
If those values are not specified, they are read from the device.
METHODS
sweep_to_level
$src->sweep_to_level($lvl,$time)
Sweep to the level $lvl in $time seconds.
set_voltage
$src->set_voltage($voltage)
Sets the output voltage to $voltage. Returns the newly set voltage.
get_voltage
Returns the currently set $voltage. The value is read from the driver cache by default. Provide the option
device_cache => 1
to read directly from the device.
set_current
$src->set_current($current)
Sets the output current to $current. Returns the newly set current.
get_current
Returns the currently set $current. The value is read from the driver cache by default. Provide the option
device_cache => 1
to read directly from the device.
set_level
$src->set_level($lvl)
Sets the level $lvl in the current operation mode.
get_level
$lvl = $src->get_level()
Returns the currently set level. Use
device_cache => 1
to enforce a reading directly from the device.
set_range($range)
Fixed voltage mode
10E-3 10mV
100E-3 100mV
1E+0 1V
10E+0 10V
30E+0 30V
Fixed current mode
1E-3 1mA
10E-3 10mA
100E-3 100mA
200E-3 200mA
Please use the format on the left for the range command.
program_run($program)
Runs a program stored on the YokogawaGS200. If no prgram name is given, the currently loaded program is executed.
program_pause
Pauses the currently running program.
program_continue
Continues the paused program.
set_function($function)
Sets the source function. The Yokogawa supports the values
"CURR" for current mode and "VOLT" for voltage mode.
Returns the newly set source function.
set_voltage_limit($limit)
Sets a voltage limit to protect the device. Returns the new voltage limit.
set_current_limit($limit)
See set_voltage_limit.
output_on()
Sets the output switch to on and returns the new value of the output status.
output_off()
Sets the output switch to off. The instrument outputs no voltage or current then, no matter what voltage you set. Returns the new value of the output status.
get_error()
Queries the error code from the device. This is a very useful thing to do when you are working remote and the source is not responding.
get_output()
get_range()
CAVEATS
probably many
SEE ALSO
Lab::Instrument
The YokogawaGP200 class is a Lab::Instrument (Lab::Instrument).
Lab::Instrument::Source
The YokogawaGP200 class is a Source (Lab::Instrument::Source)
AUTHOR/COPYRIGHT
(c) 2004-2006 Daniel Schröer
(c) 2007-2010 Daniel Schröer, Daniela Taubert, Andreas K. Hüttel, and others
(c) 2011 Florian Olbrich, Andreas K. Hüttel
(c) 2012-2013 Alois Dirnaichner, Andreas K. Hüttel
This library is free software; you can redistribute it and/or modify it under the same terms as Perl itself.