NAME

Lab::Moose::Instrument::ZI_MFLI - Zurich Instruments MFLI Lock-in Amplifier

VERSION

version 3.680

SYNOPSIS

use Lab::Moose;

my $mfli = instrument(
    type => 'ZI_MFLI',
    connection_type => 'Zhinst',
    connection_options => {
        host => '132.188.12.13',
        port => 8004,
    });

$mfli->set_frequency(value => 10000);

# Set time constants of first two demodulators to 0.5 sec:
$mfli->set_tc(demod => 0, value => 0.5);
$mfli->set_tc(demod => 1, value => 0.5);

# Read out demodulators:
my $xy_0 = $mfli->get_xy(demod => 0);
my $xy_1 = $mfli->get_xy(demod => 1);
say "x_0, y_0: ", $xy_0->{x}, ", ", $xy_0->{y};

METHODS

If the MFLI has the Impedance Analyzer option, calling some of the following setter options might be without effect. E.g. if the Bandwith Control option of the Impedance Analyzer module is set, manipulating the time constant with set_tc will not work.

get_frequency

my $freq = $mfli->get_frequency();

Get oscillator frequency.

get_frq

Alias for "get_frequency".

set_frequency

$mfli->set_frequency(value => 10000);

Set oscillator frequency.

set_frq

Alias for "set_frequency".

get_voltage_sens

my $sens = $mfli->get_voltage_sens();

Get sensitivity (range) of voltage input.

set_voltage_sens

$mfli->set_voltage_sens(value => 1);

Set sensitivity (range) of voltage input.

get_current_sens

my $sens = $mfli->get_current_sens();

Get sensitivity (range) of current input.

set_current_sens

$mfli->set_current_sens(value => 100e-6);

Set sensitivity (range) of current input.

get_amplitude

my $amplitude = $mfli->get_amplitude();

Get amplitude of voltage output.

set_amplitude

$mfli->set_amplitude(value => 300e-3);

Set amplitude of voltage output.

get_amplitude_range

my $amplitude_range = $mfli->get_amplitude_range();

Get range of voltage output.

set_amplitude_range

$mfli->set_amplitude_range(value => 1);

Set amplitude of voltage output.

set_output_status

$mfli->set_output_status(value => 1); # Enable output
$mfli->set_output_status(value => 0); # Disable output

get_offset_voltage

my $offset = $mfli->get_offset_voltage();

Get DC offset.

set_offset_voltage

$mfli->set_offset_voltage(value => 1e-3);

Set DC offset.

set_offset_status

$mfli->set_offset_status(value => 1); # Enable offset voltage
$mfli->set_offset_status(value => 0); # Disable offset voltage

get_phase

my $phase = $mfli->get_phase(demod => 0);

Get demodulator phase shift.

set_phase

$mfli->set_phase(demod => 0, value => 10);

Set demodulator phase.

get_tc

my $tc = $mfli->get_tc(demod => 0);

Get demodulator time constant.

set_tc

$mfli->set_tc(demod => 0, value => 0.5);

Set demodulator time constant.

get_order

my $order = $mfli->get_order(demod => 0);

Get demodulator filter order.

set_order

$mfli->set_order(demod => 0, order => 4);

Set demodulator filter order.

get_xy

my $xy_0 = $mfli->get_xy(demod => 0);
my $xy_1 = $mfli->get_xy(demod => 1);

printf("x: %g, y: %g\n", $xy_0->{x}, $xy_0->{y});

Get demodulator X and Y output measurement values.

COPYRIGHT AND LICENSE

This software is copyright (c) 2019 by the Lab::Measurement team; in detail:

Copyright 2017       Andreas K. Huettel, Simon Reinhardt
          2019       Simon Reinhardt

This is free software; you can redistribute it and/or modify it under the same terms as the Perl 5 programming language system itself.