NAME

Tinkerforge::BrickletAnalogInV2 - Measures DC voltage between 0V and 42V

CONSTANTS

DEVICE_IDENTIFIER

This constant is used to identify a Analog In Bricklet 2.0.

The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.

DEVICE_DISPLAY_NAME

This constant represents the display name of a Analog In Bricklet 2.0.

CALLBACK_VOLTAGE

This constant is used with the register_callback() subroutine to specify the CALLBACK_VOLTAGE callback.

CALLBACK_ANALOG_VALUE

This constant is used with the register_callback() subroutine to specify the CALLBACK_ANALOG_VALUE callback.

CALLBACK_VOLTAGE_REACHED

This constant is used with the register_callback() subroutine to specify the CALLBACK_VOLTAGE_REACHED callback.

CALLBACK_ANALOG_VALUE_REACHED

This constant is used with the register_callback() subroutine to specify the CALLBACK_ANALOG_VALUE_REACHED callback.

FUNCTION_GET_VOLTAGE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_ANALOG_VALUE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_VOLTAGE_CALLBACK_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_VOLTAGE_CALLBACK_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_ANALOG_VALUE_CALLBACK_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_ANALOG_VALUE_CALLBACK_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_VOLTAGE_CALLBACK_THRESHOLD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_VOLTAGE_CALLBACK_THRESHOLD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_ANALOG_VALUE_CALLBACK_THRESHOLD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_ANALOG_VALUE_CALLBACK_THRESHOLD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_DEBOUNCE_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_DEBOUNCE_PERIOD

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_SET_MOVING_AVERAGE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_MOVING_AVERAGE

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTION_GET_IDENTITY

This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.

FUNCTIONS

new()

Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.

get_voltage()

Returns the measured voltage. The value is in mV and between 0V and 42V. The resolution is approximately 10mV.

If you want to get the voltage periodically, it is recommended to use the :cb:`Voltage` callback and set the period with :func:`Set Voltage Callback Period`.

get_analog_value()

Returns the value as read by a 12-bit analog-to-digital converter. The value is between 0 and 4095.

If you want the analog value periodically, it is recommended to use the :cb:`Analog Value` callback and set the period with :func:`Set Analog Value Callback Period`.

set_voltage_callback_period()

Sets the period in ms with which the :cb:`Voltage` callback is triggered periodically. A value of 0 turns the callback off.

The :cb:`Voltage` callback is only triggered if the voltage has changed since the last triggering.

The default value is 0.

get_voltage_callback_period()

Returns the period as set by :func:`Set Voltage Callback Period`.

set_analog_value_callback_period()

Sets the period in ms with which the :cb:`Analog Value` callback is triggered periodically. A value of 0 turns the callback off.

The :cb:`Analog Value` callback is only triggered if the analog value has changed since the last triggering.

The default value is 0.

get_analog_value_callback_period()

Returns the period as set by :func:`Set Analog Value Callback Period`.

set_voltage_callback_threshold()

Sets the thresholds for the :cb:`Voltage Reached` callback.

The following options are possible:

.. csv-table:: :header: "Option", "Description" :widths: 10, 100

"'x'",    "Callback is turned off"
"'o'",    "Callback is triggered when the voltage is *outside* the min and max values"
"'i'",    "Callback is triggered when the voltage is *inside* the min and max values"
"'<'",    "Callback is triggered when the voltage is smaller than the min value (max is ignored)"
"'>'",    "Callback is triggered when the voltage is greater than the min value (max is ignored)"

The default value is ('x', 0, 0).

get_voltage_callback_threshold()

Returns the threshold as set by :func:`Set Voltage Callback Threshold`.

set_analog_value_callback_threshold()

Sets the thresholds for the :cb:`Analog Value Reached` callback.

The following options are possible:

.. csv-table:: :header: "Option", "Description" :widths: 10, 100

"'x'",    "Callback is turned off"
"'o'",    "Callback is triggered when the analog value is *outside* the min and max values"
"'i'",    "Callback is triggered when the analog value is *inside* the min and max values"
"'<'",    "Callback is triggered when the analog value is smaller than the min value (max is ignored)"
"'>'",    "Callback is triggered when the analog value is greater than the min value (max is ignored)"

The default value is ('x', 0, 0).

get_analog_value_callback_threshold()

Returns the threshold as set by :func:`Set Analog Value Callback Threshold`.

set_debounce_period()

Sets the period in ms with which the threshold callbacks

* :cb:`Voltage Reached`, * :cb:`Analog Value Reached`

are triggered, if the thresholds

* :func:`Set Voltage Callback Threshold`, * :func:`Set Analog Value Callback Threshold`

keep being reached.

The default value is 100.

get_debounce_period()

Returns the debounce period as set by :func:`Set Debounce Period`.

set_moving_average()

Sets the length of a `moving averaging <https://en.wikipedia.org/wiki/Moving_average>`__ for the voltage.

Setting the length to 1 will turn the averaging off. With less averaging, there is more noise on the data.

The range for the averaging is 1-50.

The default value is 50.

get_moving_average()

Returns the length of the moving average as set by :func:`Set Moving Average`.

get_identity()

Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.

The position can be 'a', 'b', 'c' or 'd'.

The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|