NAME
Tinkerforge::BrickletCO2 - Measures CO2 concentration in ppm
CONSTANTS
- DEVICE_IDENTIFIER
-
This constant is used to identify a CO2 Bricklet.
The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.
- DEVICE_DISPLAY_NAME
-
This constant represents the display name of a CO2 Bricklet.
- CALLBACK_CO2_CONCENTRATION
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_CO2_CONCENTRATION callback.
- CALLBACK_CO2_CONCENTRATION_REACHED
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_CO2_CONCENTRATION_REACHED callback.
- FUNCTION_GET_CO2_CONCENTRATION
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_CO2_CONCENTRATION_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_CO2_CONCENTRATION_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_IDENTITY
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
FUNCTIONS
- new()
-
Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.
- get_co2_concentration()
-
Returns the measured CO2 concentration. The value is in `ppm (parts per million) <https://en.wikipedia.org/wiki/Parts-per_notation>`__ and between 0 to 10000.
If you want to get the CO2 concentration periodically, it is recommended to use the :cb:`CO2 Concentration` callback and set the period with :func:`Set CO2 Concentration Callback Period`.
- set_co2_concentration_callback_period()
-
Sets the period in ms with which the :cb:`CO2 Concentration` callback is triggered periodically. A value of 0 turns the callback off.
The :cb:`CO2 Concentration` callback is only triggered if the CO2 concentration has changed since the last triggering.
The default value is 0.
- get_co2_concentration_callback_period()
-
Returns the period as set by :func:`Set CO2 Concentration Callback Period`.
- set_co2_concentration_callback_threshold()
-
Sets the thresholds for the :cb:`CO2 Concentration Reached` callback.
The following options are possible:
.. csv-table:: :header: "Option", "Description" :widths: 10, 100
"'x'", "Callback is turned off" "'o'", "Callback is triggered when the CO2 concentration is *outside* the min and max values" "'i'", "Callback is triggered when the CO2 concentration is *inside* the min and max values" "'<'", "Callback is triggered when the CO2 concentration is smaller than the min value (max is ignored)" "'>'", "Callback is triggered when the CO2 concentration is greater than the min value (max is ignored)"
The default value is ('x', 0, 0).
- get_co2_concentration_callback_threshold()
-
Returns the threshold as set by :func:`Set CO2 Concentration Callback Threshold`.
- set_debounce_period()
-
Sets the period in ms with which the threshold callbacks
* :cb:`CO2 Concentration Reached`,
are triggered, if the thresholds
* :func:`Set CO2 Concentration Callback Threshold`,
keep being reached.
The default value is 100.
- get_debounce_period()
-
Returns the debounce period as set by :func:`Set Debounce Period`.
- get_identity()
-
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c' or 'd'.
The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|