NAME
Tinkerforge::BrickletIndustrialDualAnalogIn - Measures two DC voltages between -35V and +35V with 24bit resolution each
CONSTANTS
- DEVICE_IDENTIFIER
-
This constant is used to identify a Industrial Dual Analog In Bricklet.
The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.
- DEVICE_DISPLAY_NAME
-
This constant represents the display name of a Industrial Dual Analog In Bricklet.
- CALLBACK_VOLTAGE
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_VOLTAGE callback.
- CALLBACK_VOLTAGE_REACHED
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_VOLTAGE_REACHED callback.
- FUNCTION_GET_VOLTAGE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_VOLTAGE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_VOLTAGE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_VOLTAGE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_VOLTAGE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_SAMPLE_RATE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_SAMPLE_RATE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_CALIBRATION
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_CALIBRATION
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_ADC_VALUES
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_IDENTITY
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
FUNCTIONS
- new()
-
Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.
- get_voltage()
-
Returns the voltage for the given channel.
If you want to get the voltage periodically, it is recommended to use the :cb:`Voltage` callback and set the period with :func:`Set Voltage Callback Period`.
- set_voltage_callback_period()
-
Sets the period with which the :cb:`Voltage` callback is triggered periodically for the given channel. A value of 0 turns the callback off.
The :cb:`Voltage` callback is only triggered if the voltage has changed since the last triggering.
- get_voltage_callback_period()
-
Returns the period as set by :func:`Set Voltage Callback Period`.
- set_voltage_callback_threshold()
-
Sets the thresholds for the :cb:`Voltage Reached` callback for the given channel.
The following options are possible:
.. csv-table:: :header: "Option", "Description" :widths: 10, 100
"'x'", "Callback is turned off" "'o'", "Callback is triggered when the voltage is *outside* the min and max values" "'i'", "Callback is triggered when the voltage is *inside* the min and max values" "'<'", "Callback is triggered when the voltage is smaller than the min value (max is ignored)" "'>'", "Callback is triggered when the voltage is greater than the min value (max is ignored)"
- get_voltage_callback_threshold()
-
Returns the threshold as set by :func:`Set Voltage Callback Threshold`.
- set_debounce_period()
-
Sets the period with which the threshold callback
* :cb:`Voltage Reached`
is triggered, if the threshold
* :func:`Set Voltage Callback Threshold`
keeps being reached.
- get_debounce_period()
-
Returns the debounce period as set by :func:`Set Debounce Period`.
- set_sample_rate()
-
Sets the sample rate. The sample rate can be between 1 sample per second and 976 samples per second. Decreasing the sample rate will also decrease the noise on the data.
- get_sample_rate()
-
Returns the sample rate as set by :func:`Set Sample Rate`.
- set_calibration()
-
Sets offset and gain of MCP3911 internal calibration registers.
See MCP3911 datasheet 7.7 and 7.8. The Industrial Dual Analog In Bricklet is already factory calibrated by Tinkerforge. It should not be necessary for you to use this function
- get_calibration()
-
Returns the calibration as set by :func:`Set Calibration`.
- get_adc_values()
-
Returns the ADC values as given by the MCP3911 IC. This function is needed for proper calibration, see :func:`Set Calibration`.
- get_identity()
-
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an :ref:`Isolator Bricklet <isolator_bricklet>` is always at position 'z'.
The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|