NAME
Tinkerforge::BrickletCurrent25 - Measures AC/DC current between -25A and +25A
CONSTANTS
- DEVICE_IDENTIFIER
-
This constant is used to identify a Current25 Bricklet.
The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.
- DEVICE_DISPLAY_NAME
-
This constant represents the display name of a Current25 Bricklet.
- CALLBACK_CURRENT
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_CURRENT callback.
- CALLBACK_ANALOG_VALUE
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_ANALOG_VALUE callback.
- CALLBACK_CURRENT_REACHED
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_CURRENT_REACHED callback.
- CALLBACK_ANALOG_VALUE_REACHED
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_ANALOG_VALUE_REACHED callback.
- CALLBACK_OVER_CURRENT
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_OVER_CURRENT callback.
- FUNCTION_GET_CURRENT
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_CALIBRATE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_IS_OVER_CURRENT
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_ANALOG_VALUE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_CURRENT_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_CURRENT_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_ANALOG_VALUE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_ANALOG_VALUE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_CURRENT_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_CURRENT_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_ANALOG_VALUE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_ANALOG_VALUE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_IDENTITY
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
FUNCTIONS
- new()
-
Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.
- get_current()
-
Returns the current of the sensor.
If you want to get the current periodically, it is recommended to use the :cb:`Current` callback and set the period with :func:`Set Current Callback Period`.
- calibrate()
-
Calibrates the 0 value of the sensor. You have to call this function when there is no current present.
The zero point of the current sensor is depending on the exact properties of the analog-to-digital converter, the length of the Bricklet cable and the temperature. Thus, if you change the Brick or the environment in which the Bricklet is used, you might have to recalibrate.
The resulting calibration will be saved on the EEPROM of the Current Bricklet.
- is_over_current()
-
Returns *true* if more than 25A were measured.
.. note:: To reset this value you have to power cycle the Bricklet.
- get_analog_value()
-
Returns the value as read by a 12-bit analog-to-digital converter.
.. note:: The value returned by :func:`Get Current` is averaged over several samples to yield less noise, while :func:`Get Analog Value` gives back raw unfiltered analog values. The only reason to use :func:`Get Analog Value` is, if you need the full resolution of the analog-to-digital converter.
If you want the analog value periodically, it is recommended to use the :cb:`Analog Value` callback and set the period with :func:`Set Analog Value Callback Period`.
- set_current_callback_period()
-
Sets the period with which the :cb:`Current` callback is triggered periodically. A value of 0 turns the callback off.
The :cb:`Current` callback is only triggered if the current has changed since the last triggering.
- get_current_callback_period()
-
Returns the period as set by :func:`Set Current Callback Period`.
- set_analog_value_callback_period()
-
Sets the period with which the :cb:`Analog Value` callback is triggered periodically. A value of 0 turns the callback off.
The :cb:`Analog Value` callback is only triggered if the analog value has changed since the last triggering.
- get_analog_value_callback_period()
-
Returns the period as set by :func:`Set Analog Value Callback Period`.
- set_current_callback_threshold()
-
Sets the thresholds for the :cb:`Current Reached` callback.
The following options are possible:
.. csv-table:: :header: "Option", "Description" :widths: 10, 100
"'x'", "Callback is turned off" "'o'", "Callback is triggered when the current is *outside* the min and max values" "'i'", "Callback is triggered when the current is *inside* the min and max values" "'<'", "Callback is triggered when the current is smaller than the min value (max is ignored)" "'>'", "Callback is triggered when the current is greater than the min value (max is ignored)"
- get_current_callback_threshold()
-
Returns the threshold as set by :func:`Set Current Callback Threshold`.
- set_analog_value_callback_threshold()
-
Sets the thresholds for the :cb:`Analog Value Reached` callback.
The following options are possible:
.. csv-table:: :header: "Option", "Description" :widths: 10, 100
"'x'", "Callback is turned off" "'o'", "Callback is triggered when the analog value is *outside* the min and max values" "'i'", "Callback is triggered when the analog value is *inside* the min and max values" "'<'", "Callback is triggered when the analog value is smaller than the min value (max is ignored)" "'>'", "Callback is triggered when the analog value is greater than the min value (max is ignored)"
- get_analog_value_callback_threshold()
-
Returns the threshold as set by :func:`Set Analog Value Callback Threshold`.
- set_debounce_period()
-
Sets the period with which the threshold callbacks
* :cb:`Current Reached`, * :cb:`Analog Value Reached`
are triggered, if the thresholds
* :func:`Set Current Callback Threshold`, * :func:`Set Analog Value Callback Threshold`
keep being reached.
- get_debounce_period()
-
Returns the debounce period as set by :func:`Set Debounce Period`.
- get_identity()
-
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an :ref:`Isolator Bricklet <isolator_bricklet>` is always at position 'z'.
The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|