NAME
Tinkerforge::BrickletTemperature - Measures ambient temperature with 0.5°C accuracy
CONSTANTS
- DEVICE_IDENTIFIER
-
This constant is used to identify a Temperature Bricklet.
The get_identity() subroutine and the CALLBACK_ENUMERATE callback of the IP Connection have a device_identifier parameter to specify the Brick's or Bricklet's type.
- DEVICE_DISPLAY_NAME
-
This constant represents the display name of a Temperature Bricklet.
- CALLBACK_TEMPERATURE
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_TEMPERATURE callback.
- CALLBACK_TEMPERATURE_REACHED
-
This constant is used with the register_callback() subroutine to specify the CALLBACK_TEMPERATURE_REACHED callback.
- FUNCTION_GET_TEMPERATURE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_TEMPERATURE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_TEMPERATURE_CALLBACK_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_TEMPERATURE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_TEMPERATURE_CALLBACK_THRESHOLD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_DEBOUNCE_PERIOD
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_SET_I2C_MODE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_I2C_MODE
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
- FUNCTION_GET_IDENTITY
-
This constant is used with the get_response_expected(), set_response_expected() and set_response_expected_all() subroutines.
FUNCTIONS
- new()
-
Creates an object with the unique device ID *uid* and adds it to the IP Connection *ipcon*.
- get_temperature()
-
Returns the temperature of the sensor.
If you want to get the temperature periodically, it is recommended to use the :cb:`Temperature` callback and set the period with :func:`Set Temperature Callback Period`.
- set_temperature_callback_period()
-
Sets the period with which the :cb:`Temperature` callback is triggered periodically. A value of 0 turns the callback off.
The :cb:`Temperature` callback is only triggered if the temperature has changed since the last triggering.
- get_temperature_callback_period()
-
Returns the period as set by :func:`Set Temperature Callback Period`.
- set_temperature_callback_threshold()
-
Sets the thresholds for the :cb:`Temperature Reached` callback.
The following options are possible:
.. csv-table:: :header: "Option", "Description" :widths: 10, 100
"'x'", "Callback is turned off" "'o'", "Callback is triggered when the temperature is *outside* the min and max values" "'i'", "Callback is triggered when the temperature is *inside* the min and max values" "'<'", "Callback is triggered when the temperature is smaller than the min value (max is ignored)" "'>'", "Callback is triggered when the temperature is greater than the min value (max is ignored)"
- get_temperature_callback_threshold()
-
Returns the threshold as set by :func:`Set Temperature Callback Threshold`.
- set_debounce_period()
-
Sets the period with which the threshold callback
* :cb:`Temperature Reached`
is triggered, if the threshold
* :func:`Set Temperature Callback Threshold`
keeps being reached.
- get_debounce_period()
-
Returns the debounce period as set by :func:`Set Debounce Period`.
- set_i2c_mode()
-
Sets the I2C mode. Possible modes are:
* 0: Fast (400kHz) * 1: Slow (100kHz)
If you have problems with obvious outliers in the Temperature Bricklet measurements, they may be caused by EMI issues. In this case it may be helpful to lower the I2C speed.
It is however not recommended to lower the I2C speed in applications where a high throughput needs to be achieved.
.. versionadded:: 2.0.1$nbsp;(Plugin)
- get_i2c_mode()
-
Returns the I2C mode as set by :func:`Set I2C Mode`.
.. versionadded:: 2.0.1$nbsp;(Plugin)
- get_identity()
-
Returns the UID, the UID where the Bricklet is connected to, the position, the hardware and firmware version as well as the device identifier.
The position can be 'a', 'b', 'c', 'd', 'e', 'f', 'g' or 'h' (Bricklet Port). A Bricklet connected to an :ref:`Isolator Bricklet <isolator_bricklet>` is always at position 'z'.
The device identifier numbers can be found :ref:`here <device_identifier>`. |device_identifier_constant|