TITLE
Parrot Calling Conventions
VERSION
1
CURRENT
Maintainer: Dan Sugalski
Class: Internals
PDD Number: 03
Version: 1
Status: Developing
Last Modified: 26 April 2002
PDD Format: 1
Language: English
HISTORY
CHANGES
ABSTRACT
This PDD describes Parrot's inter-routine calling conventions.
DESCRIPTION
Responsibility for environment preservation
The caller is responsible for preserving any environment it is interested in keeping. This includes any and all registers, lexical scoping and scratchpads, opcode libraries, and so forth.
Use of the saveall
opcode is recommended if the caller wishes to save everything, and the restoreall
opcode to restore everything saveall
saved.
Calling conventions
The following registers are used in calling all subs and methods
- P0
-
Holds the object representing the subroutine.
- P1
-
Holds the continuation for the caller, assuming this sub was called with callcc. Otherwise NULL.
- P2
-
Holds the object the sub was called on. (For method calls)
- I0
-
True if the sub is being called with prototyped parameters.
- I1
-
The number of items pushed onto the stack.
The following registers are used only when calling a subroutine for which there is a compile-time prototype.
- I5 through I31
-
The first 27 integer parameters.
- S5 through S31
-
The first 27 string parameters.
- N5 through N31
-
The first 27 numeric parameters.
- P5 through P31
-
The first 27 PMC parameters.
All overflow parameters, and all parameters for subs called without a known prototype, are pushed on the stack in reverse order--that is the topmost entry on the stack is the first entry in the parameter list, and the bottom entry the last entry in the parameter list.
The PMC for a hash, array, or list is passed if one of the entries in the parameter list is a hash, array, or list. The aggregate is not flattened. (Though when accessing the parameters it may be)
Parameters are passed in S, I, and N registers only if the sub's prototype specifically indicates it takes parameters of that type.
Note that it doesn't matter what the order of the integer, string, numeric, and PMC parameters are in the parameter list up until overflow occurs.
Return conventions
On return from a function, the following registers are set. Return values are placed in registers only if the function is prototyped to do so. All values on the stack are in reverse order, such that the top value on the stack is the first value returned.
- I0
-
Holds the number of return values on the stack.
- I1
-
Holds the number of return values in integer registers.
- I2
-
Holds the number of return values in string registers.
- I3
-
Holds the number of return values in PMC registers.
- I4
-
Holds the number of return valies in numeric registers.
- P5-P31
-
PMC return values
- I5-I31
-
Integer return values
- S5-S31
-
String return values
- N5-N31
-
Numeric return values
- stack
-
Overflow values, or values for functions that don't have a return prototype.