NAME
Mojo::Server::Hypnotoad - ALL GLORY TO THE HYPNOTOAD!
SYNOPSIS
use Mojo::Server::Hypnotoad;
my $hypnotoad = Mojo::Server::Hypnotoad->new;
$hypnotoad->run('/home/sri/myapp.pl');
DESCRIPTION
Mojo::Server::Hypnotoad is a full featured, UNIX optimized, preforking non-blocking I/O HTTP and WebSocket server, built around the very well tested and reliable Mojo::Server::Prefork, with IPv6, TLS, Comet (long polling), keep-alive, connection pooling, timeout, cookie, multipart, multiple event loop and hot deployment support that just works. Note that the server uses signals for process management, so you should avoid modifying signal handlers in your applications.
To start applications with it you can use the hypnotoad script, for Mojolicious and Mojolicious::Lite applications it will default to production
mode.
$ hypnotoad myapp.pl
Server available at http://127.0.0.1:8080.
You can run the same command again for automatic hot deployment.
$ hypnotoad myapp.pl
Starting hot deployment for Hypnotoad server 31841.
This second invocation will load the application again, detect the process id file with it, and send a "USR2" signal to the already running server.
For better scalability (epoll, kqueue) and to provide IPv6 as well as TLS support, the optional modules EV (4.0+), IO::Socket::IP (0.20+) and IO::Socket::SSL (1.84+) will be used automatically by Mojo::IOLoop if they are installed. Individual features can also be disabled with the MOJO_NO_IPV6
and MOJO_NO_TLS
environment variables.
See "DEPLOYMENT" in Mojolicious::Guides::Cookbook for more.
MANAGER SIGNALS
The Mojo::Server::Hypnotoad manager process can be controlled at runtime with the following signals.
INT, TERM
Shutdown server immediately.
QUIT
Shutdown server gracefully.
TTIN
Increase worker pool by one.
TTOU
Decrease worker pool by one.
USR2
Attempt zero downtime software upgrade (hot deployment) without losing any incoming connections.
Manager (old)
|- Worker [1]
|- Worker [2]
|- Worker [3]
|- Worker [4]
+- Manager (new)
|- Worker [1]
|- Worker [2]
|- Worker [3]
+- Worker [4]
The new manager will automatically send a "QUIT" signal to the old manager and take over serving requests after starting up successfully.
WORKER SIGNALS
Mojo::Server::Hypnotoad worker processes can be controlled at runtime with the following signals.
INT, TERM
Stop worker immediately.
QUIT
Stop worker gracefully.
SETTINGS
Mojo::Server::Hypnotoad can be configured with the following settings, see "Hypnotoad" in Mojolicious::Guides::Cookbook for examples.
accept_interval
accept_interval => 0.5
Interval in seconds for trying to reacquire the accept mutex, defaults to 0.025
. Note that changing this value can affect performance and idle CPU usage.
accepts
accepts => 100
Maximum number of connections a worker is allowed to accept before stopping gracefully, defaults to 1000
. Setting the value to 0
will allow workers to accept new connections indefinitely. Note that up to half of this value can be subtracted randomly to improve load balancing, and that worker processes will stop sending heartbeat messages once the limit has been reached.
backlog
backlog => 128
Listen backlog size, defaults to SOMAXCONN
.
clients
clients => 100
Maximum number of concurrent client connections per worker process, defaults to 1000
. Note that high concurrency works best with applications that perform mostly non-blocking operations, to optimize for blocking operations you can decrease this value and increase "workers" instead for better performance.
graceful_timeout
graceful_timeout => 15
Maximum amount of time in seconds stopping a worker gracefully may take before being forced, defaults to 20
.
group
group => 'staff'
Group name for worker processes.
heartbeat_interval
heartbeat_interval => 3
Heartbeat interval in seconds, defaults to 5
.
heartbeat_timeout
heartbeat_timeout => 2
Maximum amount of time in seconds before a worker without a heartbeat will be stopped gracefully, defaults to 20
.
inactivity_timeout
inactivity_timeout => 10
Maximum amount of time in seconds a connection can be inactive before getting closed, defaults to 15
. Setting the value to 0
will allow connections to be inactive indefinitely.
keep_alive_requests
keep_alive_requests => 50
Number of keep-alive requests per connection, defaults to 25
.
listen
listen => ['http://*:80']
List of one or more locations to listen on, defaults to http://*:8080
. See also "listen" in Mojo::Server::Daemon for more examples.
lock_file
lock_file => '/tmp/hypnotoad.lock'
Full path of accept mutex lock file prefix, to which the process id will be appended, defaults to a random temporary path.
lock_timeout
lock_timeout => 0.5
Maximum amount of time in seconds a worker may block when waiting for the accept mutex, defaults to 1
. Note that changing this value can affect performance and idle CPU usage.
multi_accept
multi_accept => 100
Number of connections to accept at once, defaults to 50
.
pid_file
pid_file => '/var/run/hypnotoad.pid'
Full path to process id file, defaults to hypnotoad.pid
in the same directory as the application. Note that this value can only be changed after the server has been stopped.
proxy
proxy => 1
Activate reverse proxy support, which allows for the X-Forwarded-For
and X-Forwarded-Proto
headers to be picked up automatically.
upgrade_timeout
upgrade_timeout => 45
Maximum amount of time in seconds a zero downtime software upgrade may take before getting canceled, defaults to 60
.
user
user => 'sri'
Username for worker processes.
workers
workers => 10
Number of worker processes, defaults to 4
. A good rule of thumb is two worker processes per CPU core for applications that perform mostly non-blocking operations, blocking operations often require more and benefit from decreasing the number of concurrent "clients" (often as low as 1
).
ATTRIBUTES
Mojo::Server::Hypnotoad implements the following attributes.
prefork
my $prefork = $hypnotoad->prefork;
$hypnotoad = $hypnotoad->prefork(Mojo::Server::Prefork->new);
Mojo::Server::Prefork object this server manages.
upgrade_timeout
my $timeout = $hypnotoad->upgrade_timeout;
$hypnotoad = $hypnotoad->upgrade_timeout(15);
Maximum amount of time in seconds a zero downtime software upgrade may take before getting canceled, defaults to 60
.
METHODS
Mojo::Server::Hypnotoad inherits all methods from Mojo::Base and implements the following new ones.
configure
$hypnotoad->configure('hypnotoad');
Configure server from application settings.
run
$hypnotoad->run('script/myapp');
Run server for application.