NAME
Lab::Moose::Connection::Socket - Transfer IEEE 488.2 / SCPI messages over TCP
VERSION
version 3.920
SYNOPSIS
use
Lab::Moose;
my
$instrument
= instrument(
type
=>
'random_instrument'
,
connection_type
=>
'Socket'
,
connection_options
=> {
host
=>
'132.199.11.2'
,
port
=> 5025
},
);
DESCRIPTION
This connection uses IO::Socket::INET to interface with the operating system's TCP stack. This works on most operating systems without installing any additional software.
Without knowing the syntax of the used command-messages there is no way for the connection to determine when Read
is finished. This is unlike GPIB, USBTMC, or VXI-11 which have explicit End of Message indicators. To deal with this, the read_length
parameter has the following semantics:
Read
is given an explicitread_length
parameter-
Keep calling sysread until
read_length
bytes are read. Read
is not given an explicitread_length
parameter-
Do a single sysread with the connections default
read_length
.
For SCPI definite length blocks you will have to give the exact block length with the read_length
parameter.